SSVD Lincoln Distribution Block

Price range: R3,364.61 through R4,478.03

(1 customer review)

The SSVD Lincoln SKF distribution blocks may be incorporated into a manual or automated Quicklub system, featuring adjustable output per outlet.

Please contact Ultra-Flow if installation is required. sales@ultra-flow.com

Description

SSVD Lincoln progressive blocks for Quicklub progressive systems are fully adjustable per outlet pair, ensuring more precise lubrication per point and meeting lubricant requirements at a more effective rate. This is achieved through the use of metering screws, which allows for the easy setup of outputs per point. The SSVD Lincoln progressive block can be integrated into any existing Quicklub progressive systems and can operate with the LINCOLN SSV distribution blocks.

Specifications

Construction Material: Carbon Steel
Max. Operating Pressure: 5076 psi / 350 bar
Outlet/Cycle Per Outlet: Min. .0049/.08 / Max. .110/1 cc
Lubricant Inlet: ⅛” NPTF(F)
Lubricant Outlet: M10x1
Operating Temperature Range: – 13°F (-25°C) to 158°F (70°C)

 

Download Specifications ►

 

Additional information

Weight N/A
Number of ports

6, 8, 10, 12

1 review for SSVD Lincoln Distribution Block

  1. Sourabh Raj

    we are using your lincoln 06 outlet ( Push fitting type) SSVD for greese lubrication but
    its not working many times we opened and serviced it but it didn’t work.
    please suggest

    • admin

      Good day,

      There could be many underlying issues which are causing issues with the SSVD feeder. The most common issues are associated with a blockage in the system.

      Please email our sales team for assistance:

      sales@ultra-flow.com